Mineral insulated stainless steel sheathed heating cables
Finished Soldered MI Assemblies
Pro Therm manufactures ready-to-connect mineral-insulated (MI) heating cable assemblies with soldered cold leads in its own workshop in Germany. We configure the heated length, cold-lead lengths and terminations to your specification for industrial plant, equipment manufacturers and international project partners.
Sample wiring diagrams
Examples of direct-switching connections. Click a diagram to enlarge it. Diagram labels are in German.
We will be happy to send you further sample wiring diagrams on request.
01
Ready-to-connect heating assemblies
Request a heating circuit manufactured to your specification, with a defined heated section and suitable cold leads. The transitions are prepared and soldered in our …
Request a heating circuit manufactured to your specification, with a defined heated section and suitable cold leads. The transitions are prepared and soldered in our workshop. Specify the heated length and the required connection lengths in your enquiry.
A cable designation alone does not define a finished circuit. Voltage, resistance, output, installation conditions and temperatures must be considered together. We agree the construction with you before manufacture.
A ready-to-connect unit is specified as one assembly: heated section, transitions, cold-lead ends and termination arrangement. The resistance cable must match length, voltage and required output. A unique assembly reference supports repeat orders and makes changes to length, cold leads or terminations traceable.
03
NiCr heating-conductor types
The existing single-core range with a NiCr heating conductor and stainless steel sheath includes: CrNi 10-32: 10 Ω/m · Ø 3.2 mm CrNi 6.3-32: 6.3 Ω/m · Ø 3.2 mm CrNi …
The existing single-core range with a NiCr heating conductor and stainless steel sheath includes:
CrNi 10-32: 10 Ω/m · Ø 3.2 mm CrNi 6.3-32: 6.3 Ω/m · Ø 3.2 mm CrNi 4.0-32: 4.0 Ω/m · Ø 3.2 mm CrNi 2.5-34: 2.5 Ω/m · Ø 3.4 mm CrNi 1.6-36: 1.6 Ω/m · Ø 3.6 mm CrNi 1.0-39: 1.0 Ω/m · Ø 3.9 mm CrNi 0.63-43: 0.63 Ω/m · Ø 4.3 mm CrNi 0.4-47: 0.4 Ω/m · Ø 4.7 mm CrNi 0.25-53: 0.25 Ω/m · Ø 5.3 mm
Temperature and voltage limits are checked for the specific cable type and finished heating assembly.
05
Request your specified assembly
Choose a known cable type or request selection by Pro Therm. For a finished MI assembly, the key inputs are heated length, supply voltage, both cold-lead lengths and …
Choose a known cable type or request selection by Pro Therm. For a finished MI assembly, the key inputs are heated length, supply voltage, both cold-lead lengths and quantity.
Add the application, maintain and maximum exposure temperatures, destination country and requested date. For a replacement circuit, include the existing identification and available measurements or design information. Unknown details can be marked as open.
A drawing with the heating length and separate dimensions for cold-lead ends A and B helps coordination. Please distinguish specified values from measurements of an existing unit. Marking, destination country and agreed test or documentation requirements are clarified before assembly.
07
Agree testing and unambiguous identification
Before manufacture, the drawing revision, heated length, both cold-lead sides, connection arrangement and requested identification are aligned. Resistance values need a …
Before manufacture, the drawing revision, heated length, both cold-lead sides, connection arrangement and requested identification are aligned. Resistance values need a defined reference temperature or the corresponding product data. Electrical tests, records and tolerances included in the supply are agreed in the order.
For replacement and repeat orders, a unique assembly reference links the delivered configuration to its design data. Ex suitability or local approval is assessed for the specifically confirmed assembly and intended use; it is not inferred from the metallic sheath alone.
09
Frequently asked questions
What does supplied with soldered cold leads mean? The heated section and cold leads are joined in our workshop to the agreed specification. The assembly is supplied with …
What does supplied with soldered cold leads mean?
The heated section and cold leads are joined in our workshop to the agreed specification. The assembly is supplied with the agreed termination and documentation scope. Installation and electrical connection follow the corresponding instructions.
Do I need to know the cable type?
No. You can request selection by Pro Therm. Describe the application, temperatures, supply and required geometry. For a replacement, include the existing identification and previous design information.
Can I request different cold-lead lengths?
Yes. Specify cold lead A and cold lead B separately. We review the requested construction together with cable type, output, current and connection conditions.
What information is needed for an international enquiry?
State the destination and operating country, supply voltage, application, temperatures, quantity and requested date. Add required approvals, marking and documentation language. Suitability and supply scope are confirmed for the specific assembly.
11
Related topics
High-temperature heating → Hazardous-area heat tracing → Heat-up → Controls and monitoring → Worldwide installation → Heat loss and insulation →
02
Constantan heating-conductor types
The existing single-core range with a stainless steel sheath includes the following catalogue types. Values show resistance per metre and outside diameter: CrNi 1.6-32: …
The existing single-core range with a stainless steel sheath includes the following catalogue types. Values show resistance per metre and outside diameter:
CrNi 1.6-32: 1.6 Ω/m · Ø 3.2 mm CrNi 1.0-34: 1.0 Ω/m · Ø 3.4 mm CrNi 0.63-37: 0.63 Ω/m · Ø 3.7 mm CrNi 0.4-40: 0.4 Ω/m · Ø 4.0 mm CrNi 0.25-44: 0.25 Ω/m · Ø 4.4 mm
Selection uses the complete design and the corresponding datasheet.
04
Cold leads and connection lengths
The existing range describes two single-core cold-lead constructions with a copper conductor: Copper sheath: 2.5 mm² · Ø 5.3 mm Stainless steel sheath: 2.5 mm² · Ø 5.3 …
The existing range describes two single-core cold-lead constructions with a copper conductor:
Copper sheath: 2.5 mm² · Ø 5.3 mm Stainless steel sheath: 2.5 mm² · Ø 5.3 mm Catalogue resistance for both: 0.00690 Ω/m.
Specify cold lead A and cold lead B separately, measuring the route from the heated section to the intended connection. Sheath material, transitions and termination details are matched to the surroundings and your requirements.
06
Supply scope for your project
For international enquiries, we consider the technical specification together with requirements at the place of use. State the required identification, documentation …
For international enquiries, we consider the technical specification together with requirements at the place of use. State the required identification, documentation language, test records and any hazardous-area requirements. The agreed supply scope is recorded in the quotation.
Recurring requirements can also be referenced by an agreed heating-circuit or item identifier. Availability, delivery date and any required installation work are reviewed for the individual order.
Your requirements guide the selection: tell us your preferred brand and budget range. For the complete system, we also work independently of a single manufacturer and select technically suitable heating, termination and control components for your project.
08
Standards and technical basis
Our knowledge section explains how the standards relate to the heating task, product selection and project design. Open the standards overview →
Our knowledge section explains how the standards relate to the heating task, product selection and project design.
10
Request a quotation for custom MI cable assemblies
Specify the heated length, supply voltage, required output or resistance, cold-lead length at each end and quantity. Add operating and exposure temperatures, termination …
Specify the heated length, supply voltage, required output or resistance, cold-lead length at each end and quantity. Add operating and exposure temperatures, termination requirements, drawing revision and destination country. For replacements, include the existing assembly reference or a nameplate photo. If cable selection is still open, tell us the duty and ask Pro Therm to review the configuration before manufacture.
Configure and request MI assemblies →